            -Peroxide / platinum sulfation
-Good transparency with stable mechanical properties
-Compliance with the ROHS REACH FDA specifications
-Excellent aging performance, high temperature resistance grade
-Good processability, free from extrusion- induced bubbles
| Material NO.: | PHQNC60-3E | |||
| PROPERTIES | VALUE | Typical value | UNIT | Method | 
| PHYSICAL PROPERTIES(Before aging) | ||||
| Color | — | Transparent or white | — | — | 
| Hardness,Shore A | — | 58-65 | Shore A | GB/T 531.1 | 
| Plasticity | 240±40 | 226 | — | GB/T 12828 | 
| Density | 1.18±0.03 | 1.183 | g/cm^3 | GB/T 533 | 
| Tensile Strength | ≥7.5 | 9.5 | MPa | GB/T 528 | 
| Tensile Elongation@break | ≥400 | 662 | % | GB/T 528 | 
| Tear Strength | ≥25 | 49 | kN/m | GB/T 529 | 
| Oxygen Index | ≥26 | 27 | — | GB/T 10707 | 
| SHORT TERM THERMAL AGING (225℃, 240h) | ||||
| Tensile Strength | ≥4 | 6.5 | MPa | GB/T 528 | 
| Tensile Elongation@break | ≥150 | 262 | % | GB/T 528 | 
| WIRE LONG TERM THERMAL AGING (200℃,3000h) | ||||
| Winding Test | No cracking | No cracking | — | ISO 19642 | 
| Withstand Voltage | No breakdown | No breakdown | — | ISO 19642 | 
| ELECTRICAL PROPERTIES | ||||
| Volume Resistivity | ≥10^15 | 7.8×10^15 | Ω·cm | GB/T 1692 | 
| Breakdown strength | ≥20 | 25 | kV/mm | GB/T 1695 | 
| OPERATING CONDITION | ||||
| Operating temperature | –50℃ ~ 200℃ | |||
| Long term use humidity | 5% ~ 90% | |||
Platinum Catalysis: 120℃ *6min
The products meet the requirements of silicone materials for new energy vehicle cables specified in ISO19642, ISO6722, LV216-2 and other standards.